簡(jiǎn)要描述:高靈敏度毫米波功率計(jì)Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號(hào):Mm-Wave power meter
  • 更新時(shí)間:2025-03-12
  • 訪  問(wèn)  量:915

產(chǎn)品簡(jiǎn)介

品牌其他品牌產(chǎn)地類(lèi)別進(jìn)口
應(yīng)用領(lǐng)域農(nóng)林牧漁,電子/電池,汽車(chē)及零部件,電氣

詳細(xì)介紹

 

高靈敏度毫米波功率計(jì)Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計(jì)Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

全國(guó)統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號(hào)707-709室

業(yè)務(wù)咨詢微信

人人综合亚洲无线码另类,亚洲狠狠色丁香婷婷综合,色婷婷久久综合中文久久蜜桃av,精品国产乱码久久久久久1区2区 桓台县| 苏尼特左旗| 兴城市| 建瓯市| 桂平市| 富川| 南木林县| 南江县| 抚远县| 武山县| 泰和县| 上思县| 桂林市| 连南| 大港区| 鄂托克旗| 七台河市| 马鞍山市| 梅州市| 南阳市| 全椒县| 梓潼县| 江山市| 清镇市| 建瓯市| 红安县| 泾源县| 嫩江县| 宁武县| 尉氏县| 忻州市| 迁西县| 叙永县| 资阳市| 永善县| 花莲县| 婺源县| 荔波县| 崇礼县| 浙江省| 富平县|